Indirect laryngoscopy revealed right vocal cord fixed in median position. The left vocal cord was almost normal in mobility and appenrance. The tube was not visible through indirect laryngoscopy. On inspection, her chest movement as comparatively less on right side. Auscultation of the chest showed less air entry to right lung and bilatera. wheeze. X-ray neck and chest were done which showed a foreign body in trachea conforming to a P.V,C. tracheostomy tube. Chest was free other pathological finding…