Hepatitis B virus (HBV) infection is of global public health concern. Among various serological tests used for the diagnosis and screening of HBV infection, the enzyme-linked immunosorbent assay (ELISA) to detect hepatitis B surface antigen (HbsAg) is most widely used. The present study was designed to develop and standardize a cost effective in-house ELISA for the detection of HbsAg and compare its performance with two established commercial kits. The concentrations of coating antibody, conjugates and sera were fixed by checkerboard titration. Using known HBsAg positive and negative sera, four different concentrations (1, 0.5, 0.25 and 0.125 μg/well) of coating anti-HBs were applied. Similarly, serial dilutions of patients’ sera (1 in 2, 1 in 3, 1 in 5 and 1 in 9) and conjugates (1 in 2, 1 in 3, 1 in 5, 1 in 9 and 1 in 17) were evaluated by checkerboard titration. The optimal concentration of coating antibody was determined at 0.25 μg/well and 1 in 9 dilution for both conjugates and sera.